Battery Charging Time Calculator

Battery Charging Time Calculator

How long a battery takes to charge from its capacity, the charger’s current or power and the state of charge you start from — including the slow constant-voltage tail at the end.

Charging time

Capacity + charge current → hours
The rated capacity on the label.
Used to convert a charger’s watts into amps: 12, 24 or 48 V for a bank, 3.7 V for a single lithium cell.
Enter one; the other box locks and shows the equivalent.
Not all the amp-hours you push in are stored: the rest goes to gassing and heat.
Where the battery is now. A home inverter battery after a long cut is often near 30–50%.
Where the charger stops holding constant current and starts holding constant voltage: about 70–80% for lead-acid, about 85% for lithium.
In the constant-voltage tail the current decays. 0.35 reproduces the usual lead-acid pattern; set it to 1 to ignore the tail entirely.
The charger pushing current into the battery. The dots move at the charge current; in the constant-voltage tail the real current tapers, so the last stretch takes much longer than the dots suggest.
13.39hExample

150 Ah lead-acid at 12 V, 30% to 100%, 15 A charger, 80% efficient, tail from 80% at 0.35×

Advertisement

Two stages, counted separately

t = (SoCknee − SoCstart) × C ÷ (100 × I × η) + (SoCend − SoCknee) × C ÷ (100 × I × f × η)
C
battery capacity in Ah
I
charge current in A (charger watts ÷ battery volts)
η
charge efficiency: 0.8 flooded lead-acid, 0.99 lithium
f
average tail current as a fraction of I (1 = no tail)

Worked example

150 Ah lead-acid at 12 V, 30% to 100%, 15 A charger, 80% efficient, tail from 80% at 0.35×
Amp-hours to replace = (100 − 30)% × 150 = 105 Ah
Constant current 30 → 80%: 75 ÷ (15 × 0.8) = 6.25 h
Tail 80 → 100%: 30 ÷ (15 × 0.35 × 0.8) = 7.14 h
Total 13.39 h — against 7.00 h if you divided amp-hours by amps

Charging a 150 Ah lead-acid battery from 30% to full (80% efficient)

Charge currentConstant currentTailTotal
C/20 — 7.5 A trickle12.50 h14.29 h26.79 h
C/10 — 15 A (typical home inverter charger)6.25 h7.14 h13.39 h
C/5 — 30 A3.12 h3.57 h6.70 h
C/3 — 50 A1.88 h2.14 h4.02 h
The tail does not shrink as fast as the bulk stage, so doubling the charger does not halve the total. Check the battery’s own maximum charge current before going above about 0.3C.

How long a battery takes to charge

The arithmetic starts simply: to put 105 Ah back into a 150 Ah battery at 15 A takes seven hours if every amp-hour counts. Two things stretch it. First, not every amp-hour counts — a flooded lead-acid battery returns about 80% of what you push in, the rest going to gassing and heat, while lithium returns about 99%. Second, no charger holds full current to the end.

The CC/CV tail. A modern charger runs constant current until the battery reaches its voltage limit, then holds that voltage while the current decays. Battery University measures the split for lead acid: about 70% of the charge goes in during 5–8 hours of constant current, and the remaining 30% takes another 7–10 hours of topping charge. Lithium is far quicker — the constant-current stage gets to roughly 85%, and a full charge at 0.5C to 1C takes two to three hours — but the shape is the same. This page models the tail as an average current, a fraction of the charge current, from the knee to the target. At the defaults the bulk stage takes 6.25 hours and the tail 7.14 hours: 13.39 hours in total, which is why an inverter battery flattened by a long cut is often not full again by evening.

Charge current. Divide by the capacity to get the C-rate: 15 A into 150 Ah is C/10, the rate most home inverter chargers use. Lead-acid manufacturers commonly advise around 0.3C as a maximum; above that the battery gasses and heats. Lithium accepts 0.5C to 1C comfortably, but its BMS may cut the current in the cold. If your charger is quoted in watts, enter that instead and the page divides by the battery voltage — 180 W at 12 V is the same 15 A.

Solar is different. A panel’s current follows the sun, so a solar charge controller spends much of the day below its rating; size the array and the controller with the solar panel size calculator and the solar charge controller calculator rather than assuming a steady current. To see how long the charge you just put in will last, use the inverter backup time calculator.

Advertisement

Frequently asked questions

How long does it take to charge a 150Ah battery?

From 30% to full at 15 A with an 80% efficient lead-acid battery, about 13.4 hours: 6.25 hours of constant current and 7.14 hours of tapering tail.

How do I calculate battery charging time?

Amp-hours to replace ÷ (charge current × charge efficiency) for the constant-current part, then add the tail, where the average current is a fraction of the charge current. Amp-hours to replace = capacity × (target SoC − starting SoC).

Why does the last 20% take so long?

Because the charger has switched from constant current to constant voltage. As the battery fills, the voltage difference driving the current shrinks, so the current decays — exponentially, near the end. Lead acid needs that time to finish converting the plates; stopping early leaves it sulphating.

Does a bigger charger charge proportionally faster?

Only the bulk stage. Doubling the current halves the constant-current time but the tail is set by the battery’s chemistry, not the charger, so the total falls by less than half.

What charge current should I use?

Around C/10 is the traditional lead-acid figure and what most inverter chargers deliver; manufacturers typically allow up to about 0.3C. For lithium, 0.5C to 1C is normal. Always check the battery’s own datasheet.

Related calculators

References

  1. Battery University. BU-403: Charging Lead Acid: “During the constant-current charge, the battery charges to about 70 percent in 5–8 hours; the remaining 30 percent is filled with the slower topping charge that lasts another 7–10 hours.”
  2. Battery University. BU-409: Charging Lithium-ion: a full charge at 0.5C–1C takes about 2–3 hours; charge efficiency is about 99%; the cell is full when the current falls to 3–5% of the Ah rating.
  3. Rolls Battery (Surrette). Charge Efficiency — Flooded Lead-Acid Battery: “Charge efficiency for Flooded deep cycle models is typically ~80%. This should be reduced 1% per year after the third (3) year of operation.”
  4. Victron Energy. SmartShunt / BMV battery monitor manual, charge efficiency factor: “We recommend setting the charge efficiency at 99%” for lithium batteries.
  5. Vader R. Energy Unlimited. Victron Energy. Charge efficiency “will range in between 80% and 95%”; battery ageing advances “disproportionately fast” once roughly 80% depth of discharge is exceeded.