Cell EMF from Standard Electrode Potentials Calculator

Cell EMF from Standard Electrode Potentials

Pick the half-cell that is reduced and the half-cell that is oxidised and the standard cell potential is one subtraction: E°cell = E°cathode − E°anode. This page does that subtraction, holds the sign convention for you, turns the answer into ΔG° and log K, and will not let you multiply E° by the number of electrons — which is where most of the marks on this topic are lost.

Two half-cells in, one standard cell potential out

E°cell = E°cathode − E°anode
The cathode is where reduction happens, in a galvanic cell and in an electrolytic one. Every entry in this list is written as a reduction, which is the modern convention, so you can read the half-equation straight off the option. Choose the last option to type a value the list does not carry.
Locked and filled from the list above unless you chose “type my own”. Standard conditions mean 298 K, 1 mol/L for every dissolved species and 100 kPa for every gas; away from those, the potential is not E° and you want the Nernst equation page instead.
The anode is where oxidation happens. Pick the half-cell here as it is tabulated — that is, still written as a reduction. Do not flip the sign yourself: the subtraction in the formula flips it for you, and flipping it twice is the single commonest error on this topic.
Locked and filled from the list above unless you chose “type my own”. Enter the reduction potential as tabulated, however the question words it. If a question hands you an oxidation potential, negate it first and put that here.
The number of electrons that cancel when you add the two balanced half-equations. For Zn + Cu2+ it is 2; for Zn + 2Ag+ it is also 2, because the silver half-equation has to be doubled. n changes ΔG° and K and does not change E°cell. That is the whole point of the next paragraph, and of the note under the answer.
Your two half-cells, drawn to your numbers. The bar at the bottom is E°cell: it runs to the right of the zero mark and is green when the reaction is spontaneous as you have written it, and it flips to the left and turns red the moment the subtraction goes negative. The electron arrows along the top wire flip with it, because electrons always leave the electrode with the more negative potential. Swap your two choices and watch everything reverse at once. The bar stops growing past about 3.7 V so that it stays inside the frame; the number beside it keeps going.
1.1000VExample

A Daniell cell. Cu²⁺/Cu at the cathode, tabulated at +0.34 V; Zn²⁺/Zn at the anode, tabulated at −0.76 V; two electrons transferred.

Advertisement

One subtraction, and then two conversions that do need n

E°cell = E°cathode − E°anode  ·  ΔG° = −nFE°cell  ·  log10K = nE°cell ÷ (2.303RT/F)
both potentials go in as reductions
this is the convention of every modern table, and the minus sign in the formula is what turns the anode half-cell into an oxidation. If you flip the anode sign yourself and then subtract, you have flipped it twice and your answer is wrong by 2E°anode
E°cathode − E°anode
equivalently E°(reduced species) − E°(oxidised species), or E°right − E°left in the IUPAC cell-diagram convention where the right-hand electrode is the cathode. All three phrasings are the same subtraction; your board will use one of them
n
the electrons that cancel when the two balanced half-equations are added. It appears in ΔG° and in log K and is absent from E°cell, because a potential is energy per coulomb and doubling the electrons doubles both
F = 96485.33212 C/mol
the charge on a mole of electrons, exact in the present SI because it is the Avogadro constant times the elementary charge, both of which are now fixed numbers. Most questions want 96500 or 96485
2.303RT/F = 0.05916 V at 298.15 K
the quantity textbooks round to 0.0592 or 0.059. Both log K figures are given above so you can see what the rounding costs: it is about 0.07 per cent, which matters only if your answer is an exponent

Worked example

A Daniell cell. Cu²⁺/Cu at the cathode, tabulated at +0.34 V; Zn²⁺/Zn at the anode, tabulated at −0.76 V; two electrons transferred.
WRITE BOTH HALF-CELLS AS REDUCTIONS, AS THE TABLE DOES. Cu2+ + 2e− → Cu, E° = +0.34 V. Zn2+ + 2e− → Zn, E° = −0.76 V. Nothing has been decided yet about which one actually happens — that is what the subtraction decides.
SUBTRACT, CATHODE MINUS ANODE. E°cell = 0.34 − (−0.76) = +1.10 V. The double negative is the step people drop; it is worth writing the bracket in every time. Positive means the reaction runs as written: zinc dissolves, copper plates out.
DO NOT MULTIPLY BY TWO. There are two electrons, and the cell potential is still 1.10 V. If you are tempted, think of two identical Daniell cells side by side but not connected: twice the charge available, same voltage. The electrons enter the arithmetic at the next step, not this one.
NOW USE n, FOR ΔG°. ΔG° = −nFE°cell = −2 × 96485.33212 × 1.10 = −212268 J/mol, which is −212.27 kJ/mol. Per mole of electrons that is −106.13 kJ, and the two figures differ by exactly the factor of n that the voltage does not contain.
AND FOR THE EQUILIBRIUM CONSTANT. log10K = nE°cell / 0.05916 = 2 × 1.10 / 0.05916 = 37.19, so K is about 1.5 × 1037. With the rounded 0.0592 you get 37.16 instead. The reaction is, for any practical purpose, complete — which is why a zinc rod in copper sulfate solution ends up copper-coloured and the blue drains out of the liquid.
THE CHECK THAT CATCHES A SIGN ERROR. The metal higher up the reactivity series is the one that dissolves, so it must be the anode. Zinc is above copper, zinc is the anode, E°cell comes out positive. If your arithmetic says otherwise on a pair of metals you know, you have subtracted the wrong way round.
Advertisement

Four rows that the two lists above cannot say out loud

Reduction half-equationE° / V vs SHEWhat that makes it
F2 + 2e− → 2F−+2.87the strongest common oxidising agent, and it tears water apart, so it is never used in solution at all
O2 + 4H+ + 4e− → 2H2O+1.23the upper edge of the water window at pH 0: anything tabulated above this line should oxidise water, and most such reagents do so only slowly
2H+ + 2e− → H20.00defined as zero rather than measured; every other number in the table is a difference from this one
Li+ + e− → Li−3.04the most negative common value, which is why lithium cells reach the highest voltage of any practical chemistry, and why they cannot use water as a solvent
A standard electrode potential is a conventional tabulation, not a measurement anyone makes on a single electrode. No instrument can read the potential of one half-cell: you can only ever measure a difference between two. The convention is to measure everything against the standard hydrogen electrode, 2H+ + 2e− → H₂ with the hydrogen ion at unit activity and H₂ at 100 kPa, and to define that electrode as 0.00 V. Every number in this column is therefore a difference from hydrogen, agreed by convention and quoted to two decimals, and the values below are the conventional school tabulation rather than a reproduction of any one published table.

Cathode minus anode, and why n never touches the voltage

A standard electrode potential is a number in a table, and the table is a convention. You cannot measure the potential of a single half-cell, because a voltmeter has two leads and reads a difference. So chemistry agreed to measure every half-cell against one reference, the standard hydrogen electrode, and to call that reference 0.00 V. Every value in the lists above is a difference from hydrogen under standard conditions: 298 K, every dissolved species at 1 mol/L, every gas at 100 kPa. The numbers are not properties of a metal the way a melting point is; they are agreed differences, quoted to two decimals, and two textbooks can differ in the last digit without either being wrong.

The subtraction is cathode minus anode, and both numbers go in unflipped. Modern tables write every half-cell as a reduction, so the anode entry is written as a reduction even though oxidation is what happens there. The minus sign in E°cell = E°cathode − E°anode is exactly what converts it. Flip the anode sign yourself and then subtract and you have flipped it twice: the answer comes out wrong by two times the anode potential, which for zinc is 1.52 V. Your board may phrase the same subtraction as E°(reduced) − E°(oxidised), or as E°right − E°left for a cell written out as a diagram with the cathode on the right. Cambridge 9701 does not use the words cathode and anode here at all; it asks you to “combine two standard electrode potentials” and then deduce the polarity.

A positive answer means spontaneous as written; a negative answer is not a failure. It is the page telling you the cell runs the other way. Swap the two choices and the sign flips. Nothing in the chemistry has changed; you have relabelled which electrode you called the cathode, and the diagram’s EMF bar and electron arrows reverse to show it. A genuinely useless prediction would be one where the answer is near zero: there the cell sits close to equilibrium and the direction is decided by the concentrations rather than by the table.

Now the mark-losing step: n never multiplies the voltage. A potential difference is energy per unit charge, so it does not scale with how much charge you move. Double the electrons in the balanced equation and you double the charge, you double the energy, and the ratio stays put. This is why multiplying a half-equation through by two to balance the electrons leaves its E° completely unchanged — which feels wrong the first ten times. Where n does belong is in the two conversions listed under the answer: ΔG° = −nFE°cell, and log₁₀K = nE°cell ÷ (2.303RT/F). Both of those are energies, and energies are extensive.

What the table cannot tell you is whether anything will actually happen. E°cell is thermodynamics: it says which way the reaction is downhill and how far. It says nothing about speed, and the gap between the two is where real chemistry lives. Aluminium sits at −1.66 V and ought to tear water apart; it does not, because an oxide skin a few nanometres thick gets in the way. Hydrogen and oxygen evolution are both sluggish on most electrode materials, which is the only reason acidified dichromate keeps in a bottle. If what you need is a verdict rather than a number, the redox feasibility interpreter handles exactly that case, including the honest answer of “feasible but slow”.

Where this page stops. It works with standard conditions only. The moment a concentration is not 1 mol/L, a gas is not at 100 kPa or the temperature is not 298 K, the potential you want is E and not E°, and you need the Nernst equation. If you want to know how much metal a given current will actually deposit, that is Faraday’s laws of electrolysis. And a note on what this plugin cannot do: the calculator has no way to read a chemical formula you type, so the half-cells are a fixed list of selections plus a box for a value of your own. It cannot balance your equation or work out n for you — you have to add the half-equations yourself and count the electrons that cancel.

Frequently asked questions

Is it cathode minus anode, or anode minus cathode?

Cathode minus anode, with both potentials taken from the table as written, that is as reductions. The same rule in other words: E°(reduced species) − E°(oxidised species). If your cell is written out as a diagram with the cathode on the right, it is right minus left.

Do I multiply E° by the number of electrons?

No, and this is the commonest error on the topic. A potential is energy per coulomb, so it does not depend on how many coulombs you move. Multiplying a half-equation by two to balance electrons leaves its E° unchanged. The number of electrons enters ΔG° = −nFE°cell and log K, both of which are given under the answer.

Why do I get a negative cell potential?

Because you have named the electrodes the other way round from the way the reaction actually goes. That is information, not an error: the reverse reaction is spontaneous, with the magnitude shown in the swapped-electrodes row. Swap your two selections if you want the positive figure.

Are standard electrode potentials measured, or agreed?

Both, in a specific sense. Cell potentials are measured; single-electrode potentials cannot be, because every measurement is a difference. So one electrode, the standard hydrogen electrode, is defined as 0.00 V and the rest of the table is measured relative to it. The tabulation is a convention built on real measurements, which is why a biochemistry table quoted at pH 7 looks different from a chemistry table quoted at pH 0 for the same half-cell.

My textbook writes E°cell with z instead of n. Is that different?

No. Cambridge 9701 writes z and most Indian textbooks write n, and both mean the number of electrons transferred per mole of reaction. Use whichever letter your paper uses and put the same integer into this page.

Can this page tell me whether the reaction will actually happen in the lab?

Only half of it. A positive E°cell says the reaction is thermodynamically downhill under standard conditions. It cannot tell you the rate, and plenty of strongly favourable redox reactions are so slow that nothing visible happens — aluminium in water being the standard example. The interpreter linked above is the page that takes that seriously.

Related calculators

References

  1. Chemistry, Subject Code 043, Classes XI and XII (2026 to 2027), senior secondary curriculum, Central Board of Secondary Education, cbseacademic.nic.in (read 14 November 2026). Unit 2 of the Class XII course is Electrochemistry, carrying 9 of the 70 theory marks, and its topic list reads in full: “Electrochemical Cells, Galvanic Cells, Nernst Equation, Conductance of Electrolytic solutions, Electrolytic Cells and Electrolysis, Batteries, Fuel Cells, Corrosion.” What is not named there is worth as much as what is: the words Kohlrausch and Faraday appear nowhere in the Class XII unit text, although both are taught inside “Conductance of Electrolytic solutions” and “Electrolytic Cells and Electrolysis”. Quoted to establish what is in scope, not to claim any endorsement by the board.
  2. Cambridge International AS and A Level Chemistry 9701, syllabus for examination in 2025, 2026 and 2027, Cambridge Assessment International Education, cambridgeinternational.org (read 14 November 2026). Topic 24.2 asks candidates to “calculate a standard cell potential by combining two standard electrode potentials” and to “deduce the polarity of each electrode”, and Topic 24.1 asks for “the relationship F = Le between the Faraday constant, F, the Avogadro constant, L, and the charge on the electron, e” and for “the quantity of charge passed during electrolysis, using Q = It”. Two things in that syllabus are worth flagging because they make an identical question look different on two papers. It writes the Nernst equation as “E = E° + (0.059/z) log [oxidised species]/[reduced species]” — a PLUS sign, the ratio the other way up from the reaction quotient, and z where most Indian textbooks write n. And the phrase “cathode minus anode” does not appear in it at all; the subtraction is left as “combining” two potentials.
  3. CODATA Recommended Values of the Fundamental Physical Constants: 2022, NIST SP 961 (May 2024), physics.nist.gov/cuu/pdf/wall_2022.pdf (read 14 November 2026). The chart gives the Faraday constant as F = 96485.33212 C/mol and the molar gas constant as R = 8.314462618 J/(mol K), in both cases with no uncertainty quoted, because the value is exact: since the 2019 redefinition of the SI the Avogadro constant and the elementary charge are fixed numbers, so F = N(A) e and R = N(A) k are fixed too. Every constant on this page is that value, not a rounded one — the rounding happens only in the 0.0592 shortcut, which is discussed in its own right.
  4. Chemistry, Textbook for Class XII, Part I, National Council of Educational Research and Training, New Delhi — the Electrochemistry unit, which is where the standard-electrode-potential table, the Nernst equation, Faraday’s two laws of electrolysis and Kohlrausch’s law of independent migration of ions are set out for this syllabus. Cited bibliographically only: this source could not be read. ncert.nic.in serves its textbook PDFs under a robots policy that disallows automated retrieval, so nothing on this page is quoted from the chapter and no page or table number is claimed for it.