Nernst Equation Calculator

Nernst Equation Calculator

Standard conditions almost never hold. The Nernst equation is what takes you from E°cell, which is a table value, to E, which is what the cell actually does at your concentrations and your temperature. This page gives both forms — the general E = E° − (RT/nF) ln Q and the 0.0592/n shortcut — and is explicit about which one it is using where, because the shortcut is only true at 298 K.

E away from standard conditions

E = E°cell − (RT/nF) ln Q
The table value, before any concentration is taken into account. If you do not have it, build it from the two half-cells on the cell EMF page first. The Daniell cell’s 1.10 V is the default here.
Written z on a Cambridge paper and n in most Indian textbooks; same integer. It divides the slope, so doubling n halves the effect that concentration has on the voltage. That is worth noticing: a many-electron cell is a steadier cell.
Products over reactants, each raised to its coefficient, using the concentrations or pressures you actually have rather than the standard ones. Pure solids and pure liquids are left out, exactly as in Kc. You can type it in exponent form, as 1e-6. Q below 1 means the cell has barely started and the voltage is above E°; Q above 1 means it is running down.
The exact form in the headline uses this. The 0.0592 shortcut does not and cannot: it is 2.303RT/F evaluated once, at 298.15 K, and then rounded. The difference between the two is reported below so you can see when it stops being safe to use the shortcut.
E plotted against log₁₀ Q. The Nernst equation is a straight line on these axes and nothing else, which is the single most useful thing to know about it: the intercept at Q = 1 is E°cell and the gradient is −(2.303RT/nF), about −0.0592/n volts per decade at 298 K. Change n and the line tilts; change the temperature and it tilts a little more; change Q and only the dot moves, sliding along a line that has not altered at all. Where the line crosses E = 0 is log₁₀ K. The axes are fixed at ±10 decades of Q and roughly −1.6 V to +2.6 V, and the diagram says so in words when your point or your line falls outside them.
1.1887VExample

A Daniell cell with E°cell = 1.10 V, n = 2, run at 298.15 K with a reaction quotient Q = [Zn²⁺]/[Cu²⁺] = 0.001.

Advertisement

One equation, two costumes, and only one of them knows the temperature

E = E°cell − (RT/nF) ln Q  ·  E = E°cell − (0.0592/n) log10Q  (at 298 K only)  ·  at equilibrium E = 0 and log10K = nE°cell/0.0592
ln versus log₁₀
the general form uses the natural logarithm and the shortcut uses the base-ten logarithm. The 2.303 that converts between them is already baked into the 0.0592. Mixing them up changes the answer by a factor of 2.303 and looks entirely plausible, which is what makes it dangerous
0.0592 V
this is 2.303RT/F evaluated at 298.15 K and rounded. The exact figure is 0.05916 V. Some boards print 0.059 and some print 0.0591; they are the same quantity rounded differently, and the choice changes the last digit of your answer, not the method
Q, the reaction quotient
built exactly as Kc is — products over reactants, each to its coefficient, solids and pure liquids omitted — but from the concentrations you actually have. When Q = K the cell is flat and E = 0
the minus sign
Cambridge 9701 writes the same equation with a PLUS sign, because it puts [oxidised]/[reduced] where this page puts Q, and those two ratios are reciprocals. Both are right. Check which one your formula sheet gives before you trust a remembered sign
n in the denominator
n divides the slope, so a two-electron cell responds half as strongly to concentration as a one-electron cell. This is why a pH electrode, which is a one-electron response, gives a full 59 mV per pH unit

Worked example

A Daniell cell with E°cell = 1.10 V, n = 2, run at 298.15 K with a reaction quotient Q = [Zn²⁺]/[Cu²⁺] = 0.001.
FIND THE SLOPE FIRST. 2.303RT/F = 2.303 × 8.314462618 × 298.15 / 96485.33212 = 0.05916 V per decade of Q for a one-electron cell. Divide by n = 2 and each factor of ten in Q is worth 0.02958 V.
HOW MANY DECADES? log10(0.001) = −3. Not −0.001, and not ln(0.001) = −6.908 either; if you reach for a natural log here while using the 0.0592 form you will be out by a factor of 2.303.
PUT IT TOGETHER. E = 1.10 − 0.02958 × (−3) = 1.10 + 0.0887 = 1.1887 V. The sign is doing real work: Q is below 1, the logarithm is negative, the minus in front makes the whole term positive, and the cell is stronger than standard. That is a fresh cell, with plenty of copper ions and little zinc ion.
THE SHORTCUT, FOR COMPARISON. With the rounded 0.0592 you get 1.10 + 0.0888 = 1.1888 V. The two differ in the fourth decimal, which is why the shortcut is perfectly safe at room temperature and useless at 350 K, where the true slope is 0.0695 V per decade.
WHERE DOES THE CELL GO FLAT? Set E = 0: log10K = nE°cell/0.05916 = 2 × 1.10 / 0.05916 = 37.19. So the cell keeps running until [Zn2+]/[Cu2+] reaches about 1037, which in any real beaker means until the copper ions have gone. Read it off the diagram: it is where the blue line would cross the zero-volt line, far off the right of the axes.
AND THE ENERGY. ΔG = −nFE = −2 × 96485.33212 × 1.1887 = −229.39 kJ/mol, against −212.27 kJ/mol at standard conditions. The dilute product has bought about 17 kJ per mole, and it is entropy that paid for it.
Advertisement

What one factor of ten in Q is worth, in millivolts

n273 K298 K323 K350 K
154.259.264.169.5
227.129.632.134.7
318.119.721.423.2
69.09.910.711.6
Each entry is 2.303RT/nF in millivolts, computed from the CODATA 2022 values of R and F. The 298 K column for n = 1 is the famous 59 mV, and the whole table is just that number scaled by T and divided by n. Two things fall out of it. A cell with many electrons barely notices concentration, which is why fuel cells hold their voltage. And the temperature dependence is real but gentle — a 25 K rise changes the slope by under a tenth — so the 0.0592 shortcut is a good approximation over the whole of a normal laboratory, and a poor one in a furnace.

A straight line in disguise, and which of the two forms to use

Every Nernst question is the same straight line. Plot E against log₁₀ Q and you get a line whose intercept is E°cell and whose gradient is −(2.303RT/nF). That is the picture above, drawn to your numbers. Once you see it that way the whole topic simplifies: changing the concentrations slides the dot along the line, changing n tilts the line about its intercept, and changing the temperature tilts it a little more. The only thing that moves the line up or down is a different cell.

There are two forms and they are the same equation. The general one is E = E°cell − (RT/nF) ln Q, with a natural logarithm, and it works at any temperature. The school one is E = E°cell − (0.0592/n) log₁₀Q, with a base-ten logarithm, and the 0.0592 is 2.303RT/F worked out once at 298.15 K and then rounded. The 2.303 that converts ln to log₁₀ is hidden inside that constant. Use a natural log with the 0.0592 form, or a base-ten log with the RT/nF form, and your answer is wrong by a factor of 2.303 — a mistake that produces a perfectly plausible-looking voltage, which is exactly why it survives. The headline on this page uses the general form at your temperature; the row below it uses the shortcut, and is labelled as valid only at 298 K.

The sign of the Nernst term is where the physical meaning lives. If Q is less than 1 — lots of reactant, little product — then log Q is negative, the minus sign makes the whole term positive, and E is above E°cell. A fresh cell is stronger than its table value. As the reaction proceeds Q climbs, the term eats into the voltage, and when Q finally reaches K the potential is zero and the cell is flat. That is the single sentence that connects electrochemistry to equilibrium: a flat battery is a reaction at equilibrium, not a reaction that has run out of chemicals.

Setting E to zero is how you get K. At equilibrium Q = K and E = 0, so 0 = E°cell − (0.0592/n) log₁₀K, which rearranges to log₁₀K = nE°cell/0.0592. This is one of the most-asked exam manipulations on the topic and it is nothing more than reading off where the line in the diagram crosses the zero-volt axis. It is also where n finally earns its keep: E°cell does not depend on the number of electrons, but K depends on it exponentially, so a two-electron cell at 1 V has an equilibrium constant that is the square of a one-electron cell at the same voltage.

A concentration cell is the pure case. Build a cell from the same half-cell on both sides at different concentrations and E°cell is exactly zero, because you are subtracting a number from itself. Every volt it produces comes from the Nernst term, and the cell runs until the two concentrations are equal. Set E°cell to 0 on this page and you have modelled one. The same algebra is what makes a pH electrode work: one electron, so 59 mV per pH unit at 298 K, and a thermometer built into the meter because that 59 changes with temperature.

What the equation does not know. It is thermodynamics, so it assumes equilibrium within each half-cell and tells you nothing about rate; a cell can have a healthy Nernst potential and deliver almost no current because the electrode reaction is slow. It also uses concentrations where it should strictly use activities, which starts to matter above about 0.1 mol/L — a real deviation that this page, like every school treatment, ignores. If what you want is the standard value before any of this, that is the cell EMF page. If you want to know whether the reaction will go at all, including the kinetic answer, the redox feasibility interpreter is the page for it. And for the gas laws behind the pressure terms in Q, physics owns the ideal gas equation.

Frequently asked questions

Is it 0.0592, 0.059 or 0.0591?

All three are 2.303RT/F at 298.15 K, rounded to different numbers of figures; the exact value from the CODATA 2022 constants is 0.05916 V. Use whichever your board prints, because the difference shows up in the fourth decimal of a voltage. It matters more if you are computing log K, where it sits in an exponent.

Why does my answer come out 2.303 times too big or too small?

Because a natural logarithm has been used with the 0.0592 form, or a base-ten logarithm with the RT/nF form. The 2.303 is the conversion between them and it is already inside the 0.0592. Check which log button you pressed — on many calculators and in many programming languages, including the one behind this page, log means natural log.

My textbook writes the Nernst equation with a plus sign. Which is right?

Both. Cambridge 9701 gives E = E° + (0.059/z) log([oxidised]/[reduced]), and that ratio is the reciprocal of the reaction quotient for the reduction half-reaction, so the sign flips with it. If you use Q, the sign is minus. Decide which quantity you are putting in the logarithm before you decide the sign.

What happens when Q equals K?

E becomes zero and the cell is flat. That is the definition of equilibrium written in volts, and it is why setting E = 0 in the Nernst equation gives you log10K = nE°cell/0.0592.

Can E be positive when E°cell is negative?

Yes, and that is one of the most useful things the equation does. A sufficiently small Q can push a thermodynamically unfavourable cell into producing a positive potential. It takes a lot of Q to do it — 0.0592/n volts per factor of ten — which is why it is more common to see the reverse: a positive E°cell going negative as the products build up.

Should I use concentration or activity?

Strictly, activity. Every school treatment, this page included, uses concentration, which is a good approximation in dilute solution and a steadily worse one above about 0.1 mol/L. The error is in the ratio inside the logarithm, so it is softened by the logarithm, but it is real and it is why precise electrochemistry uses activity coefficients.

Related calculators

References

  1. Chemistry, Subject Code 043, Classes XI and XII (2026 to 2027), senior secondary curriculum, Central Board of Secondary Education, cbseacademic.nic.in (read 14 November 2026). Unit 2 of the Class XII course is Electrochemistry, carrying 9 of the 70 theory marks, and its topic list reads in full: “Electrochemical Cells, Galvanic Cells, Nernst Equation, Conductance of Electrolytic solutions, Electrolytic Cells and Electrolysis, Batteries, Fuel Cells, Corrosion.” What is not named there is worth as much as what is: the words Kohlrausch and Faraday appear nowhere in the Class XII unit text, although both are taught inside “Conductance of Electrolytic solutions” and “Electrolytic Cells and Electrolysis”. Quoted to establish what is in scope, not to claim any endorsement by the board.
  2. Cambridge International AS and A Level Chemistry 9701, syllabus for examination in 2025, 2026 and 2027, Cambridge Assessment International Education, cambridgeinternational.org (read 14 November 2026). Topic 24.2 asks candidates to “calculate a standard cell potential by combining two standard electrode potentials” and to “deduce the polarity of each electrode”, and Topic 24.1 asks for “the relationship F = Le between the Faraday constant, F, the Avogadro constant, L, and the charge on the electron, e” and for “the quantity of charge passed during electrolysis, using Q = It”. Two things in that syllabus are worth flagging because they make an identical question look different on two papers. It writes the Nernst equation as “E = E° + (0.059/z) log [oxidised species]/[reduced species]” — a PLUS sign, the ratio the other way up from the reaction quotient, and z where most Indian textbooks write n. And the phrase “cathode minus anode” does not appear in it at all; the subtraction is left as “combining” two potentials.
  3. CODATA Recommended Values of the Fundamental Physical Constants: 2022, NIST SP 961 (May 2024), physics.nist.gov/cuu/pdf/wall_2022.pdf (read 14 November 2026). The chart gives the Faraday constant as F = 96485.33212 C/mol and the molar gas constant as R = 8.314462618 J/(mol K), in both cases with no uncertainty quoted, because the value is exact: since the 2019 redefinition of the SI the Avogadro constant and the elementary charge are fixed numbers, so F = N(A) e and R = N(A) k are fixed too. Every constant on this page is that value, not a rounded one — the rounding happens only in the 0.0592 shortcut, which is discussed in its own right.
  4. Atkins’ Physical Chemistry, P. W. Atkins, J. de Paula and J. Keeler, Oxford University Press — the electrode-potential and Nernst material, the thermodynamic relation ΔG = −nFE, and the conductivity material in which the square-root dependence of molar conductivity on concentration is derived as a limiting law for strong electrolytes rather than as a general rule. Cited bibliographically: it is a printed textbook and no copy was retrieved during authoring, so it is named as the standard treatment and not quoted.